Study 133701

Description

Description

Standards

  • International
    Nexans specification

CORE (A)

AWG46 stranded Silver plated copper alloy conductor
Fluoropolymer Insulation
Nominal diameter : 0.10 mm
AWG48 Silver plated copper spiral shield
Nominal diameter : 0.16 mm
Fluoropolymer Jacket
Diameter : 0.23 +/- 0.02 mm

CORE (B)

AWG44 stranded Silver plated copper alloy conductor
Fluoropolymer Insulation
Nominal diameter : 0.15 mm
AWG48 Silver plated copper spiral shield.
Nominal diameter : 0.21 mm
Fluoropolymer Jacket
Diameter : 0.27 +/- 0.02 mm

CORE (C)

AWG44 stranded Silver plated copper alloy conductor
Fluoropolymer Insulation
Nomianl diameter : 0.17 mm
AWG48 Silver plated copper spiral shield
Nominal diameter : 0.23 mm
Fluoropolymer Jacket
Diameter : 0.29 +/- 0.02 mm

CORE (D)

AWG42 stranded Silver plated copper alloy conductor
Fluoropolymer Insulation 
Nominal diameter : 0.17 mm

CORE (E)

AWG38 stranded Silver plated copper alloy conductor
Fluoropolymer Insulation
Diameter : 0.22 +/- 0.02 mm

CORE (F)

AWG36 stranded Silver plated copper alloy conductor
Fluoropolymer Insulation 
Diameter : 0.25 +/- 0.02 mm

CORE (G)

AWG34 stranded Silver plated copper alloy conductor.
Fluoropolymer Insulation 
Diameter : 0.29 +/- 0.02 mm

Assembly

1 Core (E) + 1 Core (F) + 1 Core (D) 
Around 2 Cores (C) + 2 Cores (B) + 1 Core (G) + 2 Cores (A) twisted.

PTFE Tape
Nominal diameter : 1.02 mm

SHIELD
AWG48 Silver plated copper alloy braid
85% coverage
Nominal diameter : 1.14 mm

JACKET
Medical PUR
Max. Diameter : 1.33 mm

 

Main Characteristics
Minimum bending radius : 5 x Overall diameter.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
Shielded and sheathed
Conductor shape
Multi stranded
Conductor material
Silver coated copper
Insulation
Fluor polymer

Dimensional characteristics

Dimensional characteristics

Approximate weight
3.46 g/m
Outer Diameter
1.31 mm

Electrical characteristics

Electrical characteristics

Operating voltage
24 V

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Very flexible

Usage characteristics

Usage characteristics

Maximum operating temperature
85 °C
Minimum operating temperature
-30 °C
RoHS compliant
Yes

Resources

Resources

Documentation

xlsx — 0 B
xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close